Login Register
Gallery CV1800 & CVMax Installs Poplar Hollow Woodworks
Advanced Search
Mount with WebDAV RSS Feed for this Album View Latest Comments View Slideshow View Slideshow (Fullscreen)

CV1800 & CVMax Installs

1. Ondablade's... ... 23. Craig... 24. Randle... 25. DWD's... 26. Poplar... 27. Kevin's... 28. CV1800... 29. My shed... ... 68. Pictures of...

Members

222 members

Poplar Hollow Woodworks

This album will record the installation of my ClearVue 1800

Date: 01/20/2008
Owner: Chris Peters
Size: 21 items
nextlast
Downdraft 1_sm
 
 

Downdraft 1_sm

One view of the down-draft table that will sit at the end of the cabinet run in the corner by the windo in the prvious photo.

Date: 01/19/2008
Views: 586
Downdraft 2_sm
 
 

Downdraft 2_sm

Second view of the down draft cabinet, look down into the top.

Date: 01/19/2008
Views: 436
Cabinet shells 1_sm
 
 

Cabinet shells 1_sm

Here are two of the cabinet carcasses for the back wall cabinets. One of the collector ducts will run in the void space between the base cabinets and the wall.

Date: 01/19/2008
Views: 404
Wall duct 1_sm
 
 

Wall duct 1_sm

Here is the run of 6" pipe that runs down the wall behind the cabinets.

Date: 01/19/2008
Views: 485
Wall duct 2_sm
 
 

Wall duct 2_sm

This id the corner the CV1800 will sit in. I hope to order the CV within the next 6 weeks once the annual bonus check comes in. Stay tuned...

Date: 01/19/2008
Views: 439
Comments: 1
080126 002
 
 

080126 002

Wifey vaccuming dust up before the first three cabinets are set on the toe kick base.

Date: 01/20/2008
Views: 509
080126 003
 
 

080126 003

First three cabinets set roughly in place. The one on the end by the window is the downdraft table.

Date: 01/20/2008
Views: 529
080126 008
 
 

080126 008

Here is a view back toward the corner where the CV 1800 will set and the space for the last two cabinets.

Date: 01/20/2008
Views: 492
080325 041
 
 

080325 041

CV 1800 Finally finds it's home

Date: 03/25/2008
Views: 437
080325 042
 
 

080325 042

Date: 03/25/2008
Views: 455
080325 044
 
 

080325 044

Here is the Carlon remote stripped from it's box in preparation for mounting in a 6x6x4 PVC box with the motor relay. When it comes to electronics, I am a stickler for neat work!

Date: 03/25/2008
Views: 498
080327 002
 
 

080327 002

And here is the circuit board with the 120v PC mount receptacle desoldered from the board and replaced with leads to connect to the relay.

Date: 03/25/2008
Views: 477
080327 004
 
 

080327 004

Component parts of the control box ready to be assembled

Date: 03/25/2008
Views: 480
080327 007
 
 

080327 007

And here is the completed box. When I pre-wired for the DC, I installed 10/3 w/ground cable. This provides the needed neutral line at the control box, which supplies the necessary 110v line to run the remote receiver board and relay coil.

Date: 03/25/2008
Views: 568
Comments: 1
080327 009
 
 

080327 009

Here's a view of the install without the filter stack so you can see the control box mounted on the wall.

Date: 03/25/2008
Views: 531
080327 011
 
 

080327 011

And a shot with the filters and bin installed. I had to replace this bin because the CV collapsed this one in a full load test. Under full load, filters attached, but no collection piping connected, the motor pulled 21.6 amps (and crushed the trash can!)

Date: 03/26/2008
Views: 630
Dust Collector 001
 
 

Dust Collector 001

Figured I better update my page, since we recently "finished" the plumbing.

Date: 12/04/2008
Views: 554
Dust Collector 003
 
 

Dust Collector 003

We could not find S7D pipe here in the Tidewater area, so we went with the SDR35 pipe.

Date: 12/04/2008
Views: 507
nextlast
Page: 1 2
Powered by Gallery v2.2